As a leader in Microcoulometric Karl Fischer analyzer manufacturer,
Nittoseiko Analytec Inc. is able to propose you the most wide choice of different configurations, from small portable system up to complete 2 channels laboratory KF analyser
CA 31 For on site analysis
Touch screen control and USB interface
Range: 10ug to 100mg H2O
Sensitivity: 0,1ug H2O
Background : Automatic correction
Can be configured with battery (option)
Available in 2 colors
Example of Application
Moisture in transformer oil
Moisture analysis on production site
Fit to all small laboratories
Take your analytical instrument with you !
We propose you a set of KF reagents from the highest quality:
AQUAMICRON Reagents: Provided in small quantity , 100ml up to 500 ml bottles for anolyte
AQUAMICRON Reagents : In small 5ml Ampoules for catholyte
Analytical standard are also available in ampoules of 5 ml
Choose the highest quality for your KF reagents
If you need more detail about the reagents or KF applications please contact us by mail, we will send you more information’s and actual prices by return either in electronic form (pdf files ) or by normal mail
CA-310
Convertible modular Karl Fischer titrator with the simplest switching or parallel measurement in coulometric or volumetric KF mode.
Universal stirring unit for the coulometric as well as for volumetric titration.
Connection of up to 4 titration cells and KF ovens, also compatible for older units from MCI
User-friendly controller with 21.4 cm touch screen for the simplest and quick control of the system, as well as access to the stored measurement data of each titration cell.
Controller and stirrer unit (titration cells) can be used with USB or be connected wirelessly for data exchange (e.g., for use in a glove box).
Unique measuring sensitivity of 5 μg H2O with the coulometric measuring cell with very good repeatability.
DATA Integrity function with a data memory for 40,000 measurements or 20 years - meets the requirements of PIC/S, GMP Annex 11, FDA 21CFR 11, and MHRA.
GMP through internal audit trail, access control, data backup and system validation. PC not necessary.
All common interfaces such as LAN, USB and RS232 are present
The instrument is suitable for the following normalized ASTM test:
- D3277-94 : Moisture Content of Oil-Impregnated Cellulosic Insulation
- D4017-90 : Water in Paint and Paint Material by Karl Fisher Method
- D4377-93 : Water in Crude Oils by Potentiometric Karl Fisher Titration
- D4672-91 : Polyurethane Raw Materials : Determination of Water Content of Polyols
- D4928-89 : Water in Crude Oils by Coulometric Karl Fisher Titration
- D5530-94 : Total Moisture of Hazardous Waste Fuel by Karl Fischer
- E203-92 : Water Using Karl Fischer Reagent
- E700-90 : Water in Gases Using Karl Fischer Reagent
- E1064-92 : Water in Organic Liquids by Coulometric Karl Fischer Titration


KF Reagents and standards
Download info
Download info